{"product_id":"900p01-0301-honeywell-120-240vac-power-supply-module","title":"900P01-0301 | Honeywell | 120\/240VAC Power Supply Module","description":"\u003ch2\u003eHoneywell 900P01-0301 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for regulated AC‑to‑DC conversion in HC900 control assemblies, the \u003cstrong\u003eHoneywell 900P01‑0301\u003c\/strong\u003e (\u003cstrong\u003e900P01‑0301\u003c\/strong\u003e power supply) provides direct electrical execution of input conditioning, inrush handling, and stable DC output delivery for controller and I\/O backplane loads.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e900P01‑0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.82 kg (shipping weight 2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e137 mm H × 72.6 mm W (5.4 in × 2.86 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003ctd\u003e1.4 A max continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInrush Current\u003c\/th\u003e\n\u003ctd\u003e40 A peak‑to‑peak for 120 ms @ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Rating\u003c\/th\u003e\n\u003ctd\u003e130 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Rating\u003c\/th\u003e\n\u003ctd\u003e58 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHold‑Up Time\u003c\/th\u003e\n\u003ctd\u003e20 ms @ 115 VAC, 60 Hz, maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse\u003c\/th\u003e\n\u003ctd\u003eInternal non‑replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWiring\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.3 mm²–3.3 mm² (12–22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Jacks\u003c\/th\u003e\n\u003ctd\u003e5 VDC, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop Stability and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eWithin Honeywell process‑control environments, the module’s regulated DC output maintains stable supply conditions for downstream analog modules carrying 4–20 mA loops. Channel‑to‑channel isolation in adjacent I\/O assemblies is preserved when proper grounding and wiring separation are maintained. Cold junction compensation (CJC) circuits in temperature modules remain unaffected due to the supply’s controlled ripple and thermal profile.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 900P01‑0301 be inserted or removed while the chassis is energized? A: Hot‑swap is not supported. The chassis must be de‑energized to avoid backplane disturbance.\u003c\/p\u003e\n\u003cp\u003eQ: Does the inrush current require upstream breaker coordination? A: Yes. The 40 A peak inrush may require coordination to prevent nuisance tripping during startup.\u003c\/p\u003e\n\u003cp\u003eQ: Are firmware updates relevant to this module? A: No. The unit contains no user‑upgradeable firmware; compatibility is electrical only.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain correct torque on screw terminals to prevent micro‑movement under vibration.\u003c\/li\u003e\n\u003cli\u003eRoute AC input wiring separately from low‑voltage DC output conductors to reduce coupling.\u003c\/li\u003e\n\u003cli\u003eBond shield grounds at a single point to avoid circulating currents.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate airflow around the module to prevent thermal buildup.\u003c\/li\u003e\n\u003cli\u003eUse test jacks only for measurement, not for powering external loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49531156398339,"sku":"900P01-0301","price":462.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/files\/409438d4f89dfac2aaffb99ff5af1877.jpg?v=1688463304","url":"https:\/\/www.runtoelectronic.com\/products\/900p01-0301-honeywell-120-240vac-power-supply-module","provider":"Runto Electric","version":"1.0","type":"link"}