{"product_id":"bently-nevada-3300-01-01-00-system-monitor-module","title":"Bently Nevada 3300\/01-01-00 System Monitor Module","description":"\u003cdiv style=\"box-sizing: content-box; margin: 0px; padding: 0px; -webkit-tap-highlight-color: rgba(0, 0, 0, 0); touch-action: manipulation;\"\u003e\n\u003ch1 class=\"\"\u003eBently Nevada 3300\/01-01-00 System Monitor Module\u003c\/h1\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"animating\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"animating\"\u003eBently Nevada 3300\/01-01-00\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003ealso cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"animating\"\u003e3300\/01\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eSystem Monitor Module,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a dedicated hardware component for machinery protection monitoring,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003ealarm management,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eand rotor dynamics signal distribution within 3300 rack frameworks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"animating\"\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"animating list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"animating\"\u003eModel Series:\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003e3300\/01 System Monitor Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"animating\"\u003eOption 01:\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eConfigured for standard 24 VDC power input and monitoring logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"animating\"\u003eOption 00:\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard base configuration with panel-mounted controls and interface channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"animating\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300\/01-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOEM Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.89 kg (1.97 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 3300 rack module profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C (-40 deg F to +185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC regulated supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65 housing tier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus, EtherNet\/IP, RS-232, RS-422\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"animating\"\u003eGap Voltage Validation and Rotor Dynamics Performance\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe monitor module manages critical machinery protection features,\u003c\/span\u003e\u003cspan\u003e including trip multiply,\u003c\/span\u003e\u003cspan\u003e alarm reset logic,\u003c\/span\u003e\u003cspan\u003e and power-up\/external inhibit functions to prevent false trips during transient turbine start-ups.\u003c\/span\u003e\u003cspan\u003e It provides buffered Keyphasor and transducer outputs directly on the front panel,\u003c\/span\u003e\u003cspan\u003e allowing eddy-current probe scaling and gap voltage validation (-10 VDC targets) to be evaluated without interrupting rack operation.\u003c\/span\u003e\u003cspan\u003e Serial and network interfaces—supporting Modbus,\u003c\/span\u003e\u003cspan\u003e EtherNet\/IP,\u003c\/span\u003e\u003cspan\u003e and RS-232\/RS-422 protocols—bridge rack data to distributed control systems and external diagnostic software for advanced rotor dynamics analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the purpose of the Trip Multiply function on the 3300\/01 module?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e The Trip Multiply feature temporarily scales alarm and danger setpoints by a specific multiplier factor during known transient conditions,\u003c\/span\u003e\u003cspan\u003e preventing nuisance shutdowns.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e Does the module provide buffered outputs for signal analysis?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e Yes,\u003c\/span\u003e\u003cspan\u003e front-panel buffered outputs supply Keyphasor and raw vibration transducer signals for diagnostic data collection and rotor analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e Is this system monitor module currently active in factory catalogs?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e No,\u003c\/span\u003e\u003cspan\u003e the model has been discontinued by the manufacturer and is primarily sourced through industrial surplus and spare parts channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure rack power is fully de-energized before inserting or extracting the 3300\/01 monitor module from the 3300 series housing chassis.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify that cabinet operating temperatures remain within the -40 deg C to +85 deg C operational range to preserve internal electronic stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoute communication cables for Modbus and EtherNet\/IP through shielded pathways,\u003c\/span\u003e\u003cspan\u003e ensuring proper ground termination to eliminate loop noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm that panel-mounted alarm reset and inhibit wiring matches plant safety logic requirements prior to system commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49835894604035,"sku":"3300\/01-01-00","price":652.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/files\/321401ecc64138c2b5efe3814e9a35a0_cb80d43c-7127-40e3-b887-0a404f82a7a4.jpg?v=1762484976","url":"https:\/\/www.runtoelectronic.com\/products\/bently-nevada-3300-01-01-00-system-monitor-module","provider":"Runto Electric","version":"1.0","type":"link"}