{"product_id":"bently-nevada-3300-30-79502-01-six-channel-temperature-monitor","title":"Bently Nevada 3300\/30 79502-01 Six-Channel Temperature Monitor","description":"\u003ch1\u003eBently Nevada 3300\/30 79502-01 Six-Channel Temperature Monitor\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 79502-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSix-Channel Temperature Monitor utilized to execute continuous temperature acquisition, alarm evaluation, and recorder output generation across Bently Nevada 3300 machinery protection platforms. The monitor processes signals from RTD and thermocouple inputs, providing independent channel supervision for machinery and process temperature measurement functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/30 79502-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSix-Channel Temperature Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e6 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirement\u003c\/td\u003e\n\u003ctd\u003eTwo rack positions (excluding positions 1 and 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouples\u003c\/td\u003e\n\u003ctd\u003eType J, K, T, E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTDs\u003c\/td\u003e\n\u003ctd\u003e100 Ohm Platinum, 10 Ohm Copper, 120 Ohm Nickel, 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 deg C or 1 deg F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1 deg C or +\/-0.5% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-2 deg C plus cold junction compensation error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 1-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Functions\u003c\/td\u003e\n\u003ctd\u003eIndividual Alert and Danger setpoints per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between inputs and internal power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eLess than 1 second for all 6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCold Junction Compensation and Temperature Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eFor thermocouple measurement applications, the 3300\/30 monitor incorporates cold junction compensation functions to account for reference junction temperature variations. Compensation accuracy directly influences overall thermocouple measurement performance and contributes to channel-to-channel consistency across the six monitored inputs.\u003c\/p\u003e\n\u003cp\u003eThe module supports both grounded and non-grounded thermocouple configurations and can be configured for multiple sensor types. Galvanic isolation between field inputs and internal system power assists in reducing measurement disturbances caused by ground loops and common-mode electrical noise, particularly in machinery monitoring environments containing high-energy rotating equipment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can different temperature sensor technologies be connected to the monitor?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module supports Type J, K, T, and E thermocouples as well as compatible 3-wire RTD configurations including 100 Ohm platinum, 10 Ohm copper, and 120 Ohm nickel sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does each temperature channel have independent alarm capability?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Individual Alert and Danger alarm setpoints can be configured for each of the six monitoring channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are retransmission outputs available for integration with external systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Recorder outputs are available in either 4-20 mA or 1-5 VDC formats for external indication, recording, or control system interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module only in compatible Bently Nevada 3300 racks and do not place it in rack positions 1 or 2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify sensor type configuration before connecting field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse dedicated thermocouple extension cable matching the installed thermocouple type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between temperature sensor wiring and power conductors to minimize electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute RTD lead wires as matched conductors to preserve measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure shield grounding practices follow site instrumentation standards and avoid multiple shield termination points unless required by plant design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify Alert and Danger setpoints before placing monitored equipment into operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform functional checks on all six input channels following installation or maintenance activities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42923019960579,"sku":"79502-01","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/62702a5554d59e911c34a0fa1e94ea18.jpg?v=1655116040","url":"https:\/\/www.runtoelectronic.com\/products\/bently-nevada-3300-30-79502-01-six-channel-temperature-monitor","provider":"Runto Electric","version":"1.0","type":"link"}