{"product_id":"bently-nevada-330104-00-18-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-18-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch2\u003eBently Nevada 330104-00-18-10-02-05 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eConfigured for contactless axial position and radial vibration execution in 3300 XL monitoring platforms, the \u003cstrong\u003eBently Nevada 330104-00-18-10-02-05\u003c\/strong\u003e (\u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe (M10 x 1 thread, reverse mount)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded Length Option (0 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-18\u003c\/strong\u003e: Overall Case Length Option (180 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Total Length Option (1.0 meter \/ 3.3 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Connector and Cable Type Option (Miniature coaxial ClickLoc connector, standard cable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Agency Approval Option (Multiple approvals including CSA, ATEX, IECEx for hazardous areas)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-18-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 thread, 180 mm case length, 1.0 meter cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven by Proximitor Sensor (-18 VDC to -24 VDC power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 reverse mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Eddy-Current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eEddy-current probe scaling depends on strict mechanical-to-electrical calibration over a 7.87 V\/mm (200 mV\/mil) linear scale when coupled with a 3300 XL Proximitor Sensor and extension cable. During physical mounting, gap voltage validation target (-10 VDC targets at center gap) ensures the probe operates within its dynamic range. Cross-talk suppression requires maintaining spatial separation between adjacent probe tips on high-speed shaft journals to prevent field overlap and false vibration readings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this probe be connected directly to a PLC or DCS analog input module?\u003c\/p\u003e\n\u003cp\u003eA: No. The probe requires a matching 3300 XL extension cable and 3300 XL Proximitor Sensor to condition the high-frequency eddy-current impedance change into a voltage output signal.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary purpose of the ClickLoc connector design?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc miniature coaxial connector provides a positive locking mechanism that prevents physical disconnection under machinery vibration without requiring specialized torque tools.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify thread engagement on the M10 x 1 reverse mount port to prevent mechanical binding prior to probe insertion.\u003c\/li\u003e\n\u003cli\u003eSet physical gap distance using a multimeter connected to the Proximitor Sensor output terminals, adjusting the probe depth until reading -10 VDC (-2.5 mm physical gap equivalent).\u003c\/li\u003e\n\u003cli\u003eMaintain minimum coaxial cable bend radius of 25.4 mm (1.0 inch) during routing to prevent core conductor damage or signal attenuation.\u003c\/li\u003e\n\u003cli\u003eInsulate the miniature coaxial ClickLoc connector using self-fusing silicone tape or connector protectors to prevent grounding against local machine casing.\u003c\/li\u003e\n\u003cli\u003eEarth the overall cable shield at the monitoring rack end only to eliminate ground loop current interference on signal lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43081010675971,"sku":"330104-00-18-10-02-05","price":654.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/de6c2aafbfc8f5bcaa2826caa04302c7.jpg?v=1658799851","url":"https:\/\/www.runtoelectronic.com\/products\/bently-nevada-330104-00-18-10-02-05-3300-xl-8-mm-proximity-probe","provider":"Runto Electric","version":"1.0","type":"link"}