{"product_id":"bently-nevada-330130-040-01-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-040-01-05 3300 XL Standard Extension Cable","description":"\u003ch1\u003eBently Nevada 330130-040-01-05 3300 XL Standard Extension Cable\u003c\/h1\u003e\n\u003cp\u003eConfigured for signal transmission between proximity probes and Proximitor sensors in 3300 XL transducer systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-040-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Extension Cable) provides direct electrical interconnection while preserving calibrated system impedance and signal integrity. The cable forms part of a matched eddy-current transducer assembly used for shaft vibration, position, and rotational monitoring measurements.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Standard Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e040:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.0 m cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eArmored cable with connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple agency approval option including hazardous area certifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-040-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eStandard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored Triaxial Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eConnector Protector Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n\u003ctd\u003e75 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL Probe and Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported System Length\u003c\/td\u003e\n\u003ctd\u003e5 m or 9 m Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003eFEP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Design\u003c\/td\u003e\n\u003ctd\u003eCableLoc Gold-Plated Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePull Strength\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf) Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approval Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.25 kg to 0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 m Overall Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Stability and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 330130 extension cable is a calibrated component within the 3300 XL transducer system. Electrical length, cable impedance, and connector characteristics are controlled to maintain system accuracy and repeatability.\u003c\/p\u003e\n\u003cp\u003eProper matching between the proximity probe, extension cable, and Proximitor sensor is required to achieve the intended system linearity and gap voltage characteristics. During commissioning, gap voltage verification is commonly performed to confirm that the transducer system operates within its calibrated measurement region, typically centered near the standard -10 VDC operating target.\u003c\/p\u003e\n\u003cp\u003eThe triaxial cable construction and continuous shielding arrangement assist in suppressing electromagnetic interference and reducing cross-talk between adjacent monitoring channels installed on the same machine train.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the extension cable be shortened or field-spliced?\u003c\/strong\u003e\u003cbr\u003eA: No. The cable is part of a calibrated transducer system. Modifying the cable length or connector assembly can alter system characteristics and affect measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the cable require a specific total system length?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The extension cable must be matched with the appropriate 3300 XL probe and Proximitor sensor configuration to achieve the specified 5 m or 9 m system length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the connector protector?\u003c\/strong\u003e\u003cbr\u003eA: The connector protector helps reduce contamination from moisture, lubricants, and industrial contaminants while providing additional mechanical protection at the connection interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify probe, extension cable, and Proximitor sensor compatibility before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not alter cable length or replace factory-installed connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute signal cables separately from motor feeders, VFD output cables, and high-current conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield continuity throughout the complete transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrevent excessive bending, crushing, twisting, or tensile loading of the cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure CableLoc connectors are fully engaged and mechanically secured.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect armor, connectors, and protective fittings for physical damage before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm acceptable gap voltage values after installation and prior to machine startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42926667628803,"sku":"330130-040-01-05","price":562.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/0aa3760b5fa006ed6da5f29e6fec9f93.jpg?v=1655207274","url":"https:\/\/www.runtoelectronic.com\/products\/bently-nevada-330130-040-01-05-3300-xl-standard-extension-cable","provider":"Runto Electric","version":"1.0","type":"link"}