{"product_id":"bently-nevada-330930-060-00-00-standard-extension-cable","title":"Bently Nevada 330930-060-00-00 Standard Extension Cable","description":"\u003ch1\u003eBently Nevada 330930-060-00-00 3300 XL Standard Extension Cable\u003c\/h1\u003e\n\u003cp\u003eConfigured for signal transmission between proximity probes and Proximitor sensors in Bently Nevada transducer systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-060-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Standard Extension Cable) provides direct electrical interconnection within the 3300 XL machinery monitoring architecture. The cable forms part of a matched eddy-current transducer assembly and preserves calibrated signal characteristics between sensing and conditioning components.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e060 = 6.0 m (19.7 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector and Cable Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e00 = Without stainless steel armor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e00 = Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330930-060-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6.0 m (19.7 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Option\u003c\/td\u003e\n\u003ctd\u003eWithout stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL Proximity Transducer Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current transducer signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eFactory-configured extension cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProbe-to-Proximitor interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eFixed field wiring and connector attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Integrity and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 330930 extension cable is designed for use as part of a calibrated 3300 XL transducer system consisting of a proximity probe, extension cable, and Proximitor sensor. System performance depends on maintaining the specified electrical characteristics of the complete assembly.\u003c\/p\u003e\n\u003cp\u003eExtension cable length directly contributes to transducer calibration requirements. Substituting cable lengths or mixing incompatible components may alter system response and require verification against the applicable transducer configuration.\u003c\/p\u003e\n\u003cp\u003eProper cable routing reduces electromagnetic coupling between adjacent monitoring channels. Separation from high-current conductors, motor feeders, and switching circuits helps minimize cross-talk effects and preserves measurement stability in multi-channel machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the extension cable be used with proximity probes from other transducer systems?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatibility depends on the calibration requirements of the complete transducer assembly. Probe, extension cable, and Proximitor components should be matched according to the applicable system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the extension cable generate or condition measurement signals?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The extension cable is a passive component that transfers signals between the proximity probe and the associated Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the cable length be shortened in the field?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField modification of the cable assembly is generally avoided because cable characteristics form part of the calibrated transducer system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify extension cable length matches the transducer system configuration before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect cable insulation, connectors, and shielding for shipping or handling damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute extension cables separately from power distribution wiring and motor control circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid sharp bends, crushing forces, or excessive pulling tension during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure cable runs using suitable support methods to prevent vibration-induced movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow plant grounding and shielding practices for machinery monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform channel verification after installation to confirm proper transducer system operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43055140012291,"sku":"330930-060-00-00","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/c22f45122569fa561e19bdff384725ee.jpg?v=1658222237","url":"https:\/\/www.runtoelectronic.com\/products\/bently-nevada-330930-060-00-00-standard-extension-cable","provider":"Runto Electric","version":"1.0","type":"link"}