{"product_id":"honeywell-51304418-100-mc-tamt04-analog-multiplexer-termination-module","title":"Honeywell 51304418‑100 MC‑TAMT04 Analog Multiplexer Termination Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Honeywell \u003cstrong\u003e51304418‑100 MC‑TAMT04\u003c\/strong\u003e Analog Multiplexer Termination Module consolidates multiple analog sensor signals into a single interface for distributed control systems. It provides stable signal conditioning, broad sensor compatibility, and reliable termination for industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e 51304418‑100\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eAlternate Code:\u003c\/strong\u003e MC‑TAMT04\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Analog Multiplexer Termination Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e Up to 16 analog input channels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSupported Signals:\u003c\/strong\u003e 4–20 mA, 0–10 V, thermocouples, RTDs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSignal Conditioning:\u003c\/strong\u003e Integrated filtering and conditioning circuitry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Channel‑level diagnostic capability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e High impedance to minimize signal loading\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel‑to‑channel and channel‑to‑system isolation for noise immunity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Rack\/cabinet mounted termination assembly, plug‑in design with keyed connectors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –20 °C to +70 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +85 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5%–95% RH, non‑condensing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Yes, protects against moisture, dust, and corrosive gases\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 135 × 25 × 200 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e ~2.0 kg\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Honeywell TDC 3000, Experion PKS systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMulti‑Channel Termination:\u003c\/strong\u003e Efficiently consolidates up to 16 analog inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eBroad Sensor Compatibility:\u003c\/strong\u003e Supports current loops, voltage signals, thermocouples, and RTDs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Conditioning:\u003c\/strong\u003e Stabilizes signals and reduces electrical noise\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Channel monitoring for faster troubleshooting and maintenance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Reliability:\u003c\/strong\u003e Conformal coating ensures durability in harsh environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e Isolation design enhances measurement accuracy\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Plug‑in module with keyed connectors for secure setup\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42933073346819,"sku":"51304418-100","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/5d690ab99f964b490e4db95b28ab06cd_7fc784e8-beb0-4810-8e94-c650e2841478.jpg?v=1655350504","url":"https:\/\/www.runtoelectronic.com\/products\/honeywell-51304418-100-mc-tamt04-analog-multiplexer-termination-module","provider":"Runto Electric","version":"1.0","type":"link"}