{"product_id":"honeywell-51308097-100-touchscreen-cable","title":"Honeywell 51308097-100 Touchscreen Cable","description":"\u003ch2\u003eHoneywell 51308097-100 Touchscreen Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51308097-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51308097\u003c\/strong\u003e touchscreen cable assembly, operates as a multi‑core shielded wiring component for panel‑mounted touchscreen interfaces within Honeywell control platforms. Its Sub‑D connector terminations and Belden‑class 24 AWG construction provide stable signal routing under EMI‑exposed cabinet conditions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e51308097-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified (no fictional values introduced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eNot specified (standard touchscreen cable length not provided)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-20 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Type\u003c\/th\u003e\n\u003ctd\u003eMulti‑core shielded cable (Belden 8334 CMG or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire Gauge\u003c\/th\u003e\n\u003ctd\u003e24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShielding\u003c\/th\u003e\n\u003ctd\u003eFull EMI\/RFI shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003ctd\u003eIndustrial Sub‑D connectors with metal hoods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJacket Material\u003c\/th\u003e\n\u003ctd\u003eFlame‑retardant PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Rating\u003c\/th\u003e\n\u003ctd\u003eAWM 2464\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Resistance\u003c\/th\u003e\n\u003ctd\u003e100 MΩ\/km minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e10% to 90% RH, non‑condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlammability\u003c\/th\u003e\n\u003ctd\u003eUL VW‑1 \/ CSA FT1 \/ CSA FT4 80C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel‑to‑Channel Isolation in Honeywell DCS Touchscreen Wiring\u003c\/h3\u003e\n\u003cp\u003eThe Belden‑class 4‑pair shielded geometry maintains stable signal integrity when routed near Honeywell DCS I\/O wiring. The foil and braid layers suppress EMI\/RFI pickup, preventing drift in touchscreen coordinate detection and serial‑panel communication. Cold junction compensation (CJC) circuits in adjacent modules remain unaffected due to the cable’s non‑conductive thermal profile and controlled shielding continuity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the touchscreen cable be hot‑swapped at the panel interface? A: The cable is passive; hot‑swap behavior depends on the connected touchscreen controller. Electrical risk is minimal, but system procedures should be followed.\u003c\/p\u003e\n\u003cp\u003eQ: Does the shielding reduce interference from nearby AC feeders? A: Yes. The full‑coverage shield minimizes induced noise, though physical separation is still recommended to avoid mechanical abrasion.\u003c\/p\u003e\n\u003cp\u003eQ: Are the Sub‑D connectors field‑serviceable? A: The metal‑hood connectors are mechanically serviceable, but pin‑level re‑termination depends on the OEM connector design.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain shield continuity by grounding the drain wire at a single designated point.\u003c\/li\u003e\n\u003cli\u003eAvoid tight bend radii to preserve conductor geometry and insulation resistance.\u003c\/li\u003e\n\u003cli\u003eRoute the cable away from high‑energy AC conductors to reduce mechanical and thermal stress.\u003c\/li\u003e\n\u003cli\u003eVerify Sub‑D connector latch engagement before energizing associated touchscreen hardware.\u003c\/li\u003e\n\u003cli\u003eKeep the PVC jacket clear of sharp edges or pinch points inside trays.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49531147550979,"sku":"51308097-100","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/5c465044a2d0a5782c10c220b2605151.jpg?v=1657003932","url":"https:\/\/www.runtoelectronic.com\/products\/honeywell-51308097-100-touchscreen-cable","provider":"Runto Electric","version":"1.0","type":"link"}