{"product_id":"honeywell-900b16-0202-analog-output-module","title":"Honeywell 900B16-0202 Analog Output Module","description":"\u003ch2\u003eHoneywell 900B16-0202 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900B16-0202\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900B16-0202\u003c\/strong\u003e Analog Outputs 0 to 20 mA, operates as a dedicated hardware component for multi-channel current signal transmission within HC900 controller systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e900B16-0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2 kg (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eRack-mounted form factor (HC900 cabinet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003e5 V; 350 mA max \/ 24 V; 700 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore Function\u003c\/th\u003e\n\u003ctd\u003e16 analog outputs, 0 to 20 mA, isolated in 4 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e0.1% full scale at reference conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\/A Resolution\u003c\/th\u003e\n\u003ctd\u003e13+ bits (1 part in 13332)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e500 VDC group-to-group, 500 VDC from logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad Resistance\u003c\/th\u003e\n\u003ctd\u003e750 ohms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration\u003c\/th\u003e\n\u003ctd\u003eRedundant factory calibration, field calibration per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd\u003eMonitoring of calibration and configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Verification\u003c\/th\u003e\n\u003ctd\u003eFeedback to controller to confirm current flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe module supports integration into HC900 systems where \u003cstrong\u003e4-20 mA HART loop protocol\u003c\/strong\u003e is utilized for process control. Channel grouping ensures \u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e, reducing interference across redundant outputs. Calibration data stored in non-volatile memory allows consistent diagnostics and rejection of invalid calibration versions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 900B16-0202 module be hot-swapped during operation? A: Modules are not designed for hot-swap; power-down is recommended before insertion or removal.\u003c\/p\u003e\n\u003cp\u003eQ: How does the rack limit module count with this output card? A: A maximum of 2 modules per rack is supported when powered from internal 24 V backplane supply.\u003c\/p\u003e\n\u003cp\u003eQ: What is the redundancy behavior of calibration data? A: Factory calibration is stored redundantly; invalid versions are automatically rejected, ensuring valid channel operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse the designated \u003cstrong\u003e36-position Euro style terminal block (900TCK-0001)\u003c\/strong\u003e for wiring.\u003c\/li\u003e\n\u003cli\u003eMaintain shielded cable grounding at a single point to minimize noise coupling.\u003c\/li\u003e\n\u003cli\u003eSegregate analog signal wiring from digital or high-voltage lines.\u003c\/li\u003e\n\u003cli\u003eEnsure proper airflow around modules to prevent localized heating.\u003c\/li\u003e\n\u003cli\u003eVerify load resistance does not exceed 750 ohms per channel to maintain accuracy.\u003c\/li\u003e\n\u003cli\u003ePerform field calibration per channel after installation to align with process requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49507546169603,"sku":"900B16-0202","price":658.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/0d42d46e012338c31dfe3801b2c6a238.jpg?v=1708410525","url":"https:\/\/www.runtoelectronic.com\/products\/honeywell-900b16-0202-analog-output-module","provider":"Runto Electric","version":"1.0","type":"link"}