{"product_id":"honeywell-fs-tsfire-1624-plc-termination-assembly-module","title":"Honeywell FS-TSFIRE-1624 PLC Termination Assembly Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-457\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eHoneywell FS-TSFIRE-1624\u003c\/strong\u003e\u003cspan class=\"citation-457\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Field Termination Assembly (FTA) module designed for the \u003c\/span\u003eHoneywell Safety Manager\u003cspan class=\"citation-457 citation-end-457\"\u003e\u003cspan\u003e \u003c\/span\u003e(formerly FSC) system.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt acts as the physical interface between field-mounted fire detectors and the system's digital input modules. This module is specifically engineered to handle the unique current and monitoring requirements of fire loops, ensuring high-integrity signal processing in critical life safety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"citation-456 citation-end-456\"\u003e\u003cspan\u003e \u003c\/span\u003eFS-TSFIRE-1624 (also known as 51191148-100).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 independent input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC nominal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-455\"\u003e\u003c\/span\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan class=\"citation-455 citation-end-455\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for use with Honeywell Safety Manager and Universal I\/O modules.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports both non-redundant and redundant I\/O configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCurrent-limited inputs suitable for smoke, heat, and flame detectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN rail mounting or dedicated FTA mounting frames.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScrew-terminal blocks for field wiring and high-density cables for system connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-454\"\u003e\u003c\/span\u003e\u003cstrong\u003eLoop Monitoring:\u003c\/strong\u003e\u003cspan class=\"citation-454 citation-end-454\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides integrated line monitoring to detect open or short-circuit conditions in the field wiring, meeting stringent fire safety standards.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limitation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel includes current-limiting circuitry to protect the system from field-side faults or detector malfunctions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeamlessly integrates with redundant Safety Manager I\/O modules to ensure continuous operation even if one processor fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-453\"\u003e\u003c\/span\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan class=\"citation-453 citation-end-453\"\u003e\u003cspan\u003e \u003c\/span\u003eOffers robust electrical separation between the hazardous field environment and the sensitive control logic.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with system-level software to provide detailed channel-specific health status and fault reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTϋV certified for use in SIL 3 (Safety Integrity Level 3) loops when configured as part of a complete Safety Manager system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43094432416003,"sku":"FS-TSFIRE-1624","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/7995\/4179\/products\/9eb47ba2b01a8a187b6681e80cf26c09_d6894de8-7daa-4a61-863f-75eee570b970.jpg?v=1659081990","url":"https:\/\/www.runtoelectronic.com\/products\/honeywell-fs-tsfire-1624-plc-termination-assembly-module","provider":"Runto Electric","version":"1.0","type":"link"}