Vendor: Bently Nevada

330101-00-08-10-02-00 | Bently Nevada | Proximity Probes

SKU: 330101-00-08-10-02-00
In stock: 12
Description

Bently Nevada 330101-00-08-10-02-00 3300 XL 8 mm Proximity Probe

The Bently Nevada 330101-00-08-10-02-00 serves as the primary 330101 Proximity Probe utilized to execute non-contact shaft displacement measurement across Bently Nevada 3300 XL transducer system platforms. The probe features an 8 mm tip diameter, 3/8-24 UNF threaded case, 1.0 m total length, and ClickLoc coaxial connector configuration.

Suffix Breakdown & Model Matrix

The model 330101-00-08-10-02-00 represents a specific configuration within the 3300 XL 8 mm Proximity Probe family.

  • 00: Unthreaded length, 0 mm

  • 08: Overall case length, 80 mm

  • 10: Total probe length, 1.0 m (3.3 ft)

  • 02: ClickLoc connector with standard cable

  • 00: Standard approval configuration

Hardware Specifications

Parameter Specification
Model 330101-00-08-10-02-00
Brand Bently Nevada
Product Type 3300 XL 8 mm Proximity Probe
Series 3300 XL
Origin U.S.A.
Tip Diameter 8.0 mm
Thread Size 3/8-24 UNF
Unthreaded Length 0 mm
Case Length 80 mm
Total Length 1.0 m (3.3 ft)
Connector Type ClickLoc coaxial connector
Cable Type Standard cable
Approval Option Standard configuration
Operating Temp Not specified
Power Consumption Not applicable

Eddy-Current Measurement Characteristics

The probe operates as the sensing element of a 3300 XL eddy-current transducer system. It generates a signal proportional to the distance between the probe tip and a conductive target surface. Proper transducer matching with compatible extension cables and Proximitor Sensors is required to maintain calibrated system response and gap voltage performance.

Frequently Asked Questions

Q: Is the probe interchangeable with other 3300 XL system components?
A: Yes. The probe is designed for use with compatible 3300 XL extension cables and Proximitor Sensors.

Q: What is the function of the ClickLoc connector?
A: The ClickLoc connector provides a secure coaxial connection in environments subject to mechanical vibration.

Q: Does the probe contact the rotating shaft during operation?
A: No. The probe is designed for non-contact measurement of conductive targets.

Field Installation Guidelines

  • Maintain the specified probe gap during installation and calibration.

  • Route transducer cables separately from high-voltage power wiring.

  • Protect probe cables from excessive bending and mechanical damage.

  • Verify connector engagement before system commissioning.

  • Perform gap voltage verification after installation.