330101-00-16-10-02-CN | Bently Nevada | 3300 XL 8 mm Proximity Probes
Bently Nevada 330101-00-16-10-02-CN 3300 XL 8 mm Proximity Probe
Configured for non-contact shaft displacement measurement in Bently Nevada transducer systems, the Bently Nevada 330101-00-16-10-02-CN (330101 Proximity Probe) provides direct sensing of dynamic and static shaft movement. The probe features an 8 mm tip diameter, 1.6 in case length, 1.0 m cable assembly, and ClickLoc coaxial connector configuration.
Suffix Breakdown & Model Matrix
The model 330101-00-16-10-02-CN is a configured version of the 3300 XL 8 mm Proximity Probe family.
-
330101: 3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor
-
00: Unthreaded length, 0 in
-
16: Overall case length, 1.6 in
-
10: Total length, 1.0 m (3.3 ft)
-
02: Miniature coaxial ClickLoc connector with standard cable
-
CN: Country-specific approval configuration
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 330101-00-16-10-02-CN |
| Brand | Bently Nevada |
| Product Type | 3300 XL 8 mm Proximity Probe |
| Series | 3300 XL |
| Origin | U.S.A. |
| Tip Diameter | 8.0 mm |
| Thread Size | 3/8-24 UNF |
| Unthreaded Length | 0 in |
| Case Length | 1.6 in |
| Total Length | 1.0 m (3.3 ft) |
| Connector Type | ClickLoc miniature coaxial |
| Probe Tip Material | Polyphenylene Sulfide (PPS) |
| Probe Case Material | AISI 303/304 Stainless Steel |
| Operating Temp | -51 deg C to +177 deg C |
| Weight | 0.323 kg |
| Shipping Weight | 1.3 kg |
Gap Voltage Verification
The probe operates within a calibrated 3300 XL eddy-current transducer system. Proper probe, extension cable, and Proximitor Sensor matching is required to maintain specified sensitivity and measurement accuracy. Gap voltage verification is commonly performed during commissioning to confirm correct probe positioning relative to the shaft surface.
Frequently Asked Questions
Q: Is this probe compatible with 3300 XL transducer systems?
A: Yes. The probe is designed for use with compatible 3300 XL extension cables and Proximitor Sensors.
Q: What is the function of the ClickLoc connector?
A: The ClickLoc connector provides a positive locking coaxial connection to help prevent loosening in vibration environments.
Q: Does the probe require physical contact with the shaft?
A: No. Measurement is performed using a non-contact eddy-current sensing principle.
Field Installation Guidelines
-
Maintain the specified probe gap during calibration.
-
Route probe cables separately from power and motor wiring.
-
Avoid excessive bending or mechanical stress on the cable assembly.
-
Verify shield continuity and connector engagement before startup.
-
Confirm transducer system component compatibility prior to commissioning.
330101-00-16-10-02-CN | Bently Nevada | 3300 XL 8 mm Proximity Probes