330103-00-15-10-02-00 Bently Nevada Proximity Probes
Bently Nevada 330103-00-15-10-02-00 3300 XL 8 mm Proximity Probe
The Bently Nevada 330103-00-15-10-02-00 serves as the primary 330103 Proximity Probe utilized to execute non-contact shaft vibration and displacement measurement across Bently Nevada 3300 XL transducer system platforms. The probe features an 8 mm sensing tip, 150 mm case length, 1.0 m cable assembly, and a miniature ClickLoc coaxial connector.
Suffix Breakdown & Model Matrix
The model 330103-00-15-10-02-00 is a configured version of the 3300 XL 8 mm Proximity Probe family.
-
00: Unthreaded length, 0.0 mm
-
15: Overall case length, 150 mm
-
10: Total length, 1.0 m (3.3 ft)
-
02: Miniature coaxial ClickLoc connector
-
00: Standard approval configuration
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 330103-00-15-10-02-00 |
| Brand | Bently Nevada |
| Product Type | 3300 XL 8 mm Proximity Probe |
| Series | 3300 XL |
| Probe Diameter | 8 mm |
| Unthreaded Length | 0.0 mm |
| Case Length | 150 mm |
| Total Length | 1.0 m (3.3 ft) |
| Connector Type | Miniature coaxial ClickLoc |
| Measurement Principle | Eddy-current sensing |
| Operating Temp | -40 deg C to +85 deg C |
| Weight | 0.1 kg |
| Power Consumption | Not applicable |
Eddy-Current Rotor Monitoring
The probe operates as the sensing element of a 3300 XL transducer system. Using the eddy-current principle, it measures the gap between the probe tip and a conductive target surface and converts shaft vibration, radial position, and axial displacement into proportional electrical signals for monitoring equipment. Correct probe system matching helps maintain calibrated scaling and gap voltage performance.
Frequently Asked Questions
Q: Does the probe require physical contact with the shaft?
A: No. The measurement is performed using a non-contact eddy-current sensing method.
Q: What is the purpose of the ClickLoc connector?
A: It provides a secure coaxial connection designed to resist loosening in vibration-intensive installations.
Q: Can the probe be used independently?
A: No. It is intended to operate as part of a complete 3300 XL transducer system with compatible extension cables and Proximitor Sensors.
Field Installation Guidelines
-
Maintain the specified probe gap during setup and calibration.
-
Route transducer cables separately from power and motor conductors.
-
Avoid excessive bending or mechanical loading of the cable assembly.
-
Verify connector engagement and cable integrity before startup.
-
Confirm compatibility of all transducer system components before commissioning.