Vendor: Bently Nevada

330105-02-12-90-02-00 | Bently Nevada |3300 XL 8mm Proximity Transducer System

SKU: 330105-02-12-90-02-00
In stock
Description

Bently Nevada 330105-02-12-90-02-00 3300 XL 8 mm Proximity Transducer System

The Bently Nevada 330105-02-12-90-02-00, also cataloged as the 330105 proximity transducer system, serves as a dedicated 8 mm eddy-current measurement assembly for displacement monitoring across 3300 XL platforms.

Part Number Breakdown

  • Model (330105): 3300 XL 8 mm proximity transducer system
  • Suffix (02): Standard option, miniature ClickLoc coaxial connector
  • Suffix (12): Base transducer variant (unthreaded length not specified)
  • Suffix (90): 9.0 m (29.5 ft) total cable length
  • Suffix (02): Miniature ClickLoc coaxial connector
  • Suffix (00): No agency approval required

Hardware Specifications

Parameter Specification
Model 330105-02-12-90-02-00
Brand Bently Nevada
Origin USA
Weight 0.246 kg (shipping weight 1.5 kg)
Dimensions Cable length 9.0 m; probe type 8 mm
Operating Temp Not specified
Power Consumption Passive transducer, powered via proximitor
Core Performance Eddy-current displacement measurement; miniature coaxial ClickLoc connector

Eddy-Current Probe Scaling and Cross-Talk Suppression

The 3300 XL transducer system maintains calibrated eddy-current scaling for accurate shaft displacement monitoring. Gap voltage validation targets -10 VDC reference points, ensuring linear displacement scaling across the 8 mm sensing range. Coaxial shielding and ClickLoc termination reduce cross-talk and maintain stable electrical seating in multi-probe installations.

Frequently Asked Questions

Q: Can the 330105 probe be replaced while the proximitor remains energized? A: Replacement should occur only with the channel de-energized to prevent transient gap-voltage excursions.

Q: Does the 9.0 m cable length require recalibration of the proximitor? A: No. Cable length is factory-matched and does not require recalibration.

Q: Are agency approvals mandatory for installation? A: This variant (suffix 00) does not include approvals; installation must comply with local site requirements.

Field Installation Guidelines

  • Ensure probe seating surfaces are clean to maintain mechanical stability.
  • Terminate cable shielding at the proximitor end only to prevent ground-loop formation.
  • Avoid sharp bends in the coaxial cable to preserve impedance characteristics.
  • Route cables away from high-current conductors to minimize electromagnetic interference.
  • Verify ClickLoc connector engagement before energizing the monitoring channel.