Vendor: Honeywell

Bently Nevada 3300/12-02-20-00 Power Supply Module

SKU: 3300/12-02-20-00
In stock: 5
Description

Bently Nevada 3300/12-02-20-00 Power Supply Module

The Bently Nevada 3300/12-02-20-00, also cataloged as the 3300/12 Power Supply Module, operates as a dedicated AC input supply for transducer excitation and rack backplane distribution within the 3300 Monitoring System.

Suffix Breakdown & Model Matrix

  • 3300/12: AC Power Supply Module
  • 02: High Voltage AC Input option (190–250 VAC)
  • 20: 20-slot panel/rack mount configuration
  • 00: No agency approvals (standard factory configuration)

Hardware Specifications

Parameter Specification
Model 3300/12-02-20-00
Brand Bently Nevada
Origin U.S.A
Weight ~1.4 kg (3.0 lbs)
Dimensions 2.0 in W × 8.0 in H × 13.0 in D (5.1 cm × 20.3 cm × 33.0 cm)
Operating Temp 0 deg C to +65 deg C (+32 F to +150 F)
Storage Temp -40 deg C to +85 deg C (-40 F to +185 F)
Relative Humidity Up to 95%, non-condensing
Input Voltage Range 190–250 VAC, single-phase
Input Frequency 50–60 Hz
Max Input Current 0.5 A maximum
Power-up Surge 26 A peak (12 A RMS) for one cycle
Fuse Rating 0.75 A slow-blow (convertible to 1.5 A for low-voltage jumper configuration)
Output Voltage -24 VDC (+0%, -2.5%) or -18 VDC (+1%, -2%) selectable via jumper
Protection Independent overload protection per monitor channel
System OK Relay Integrated relay tracks fault conditions via input card

Gap Voltage Validation and Rotor Dynamics Integration

The 3300/12 module supports proximitor excitation where gap voltage validation (-10 VDC reference targets) is critical for eddy-current probe scaling. This ensures accurate rotor dynamics monitoring by maintaining consistent displacement signals. The backplane distribution design suppresses cross-talk between adjacent channels, preserving fidelity in vibration and thrust position measurements.

Frequently Asked Questions (FAQ)

Q: Can the 3300/12 module be field-converted to low-voltage input? A: Yes. By altering the soldered jumper and replacing the fuse with a 1.5 A slow-blow, the input can be converted to 95–125 VAC.

Q: How does the System OK relay function? A: The relay is located behind the power supply module and drives the system OK line, reflecting fault conditions across the rack.

Q: Are transducer outputs protected against overload? A: Yes. Each monitor circuit board integrates independent overload protection for transducer voltages.

Field Installation Guidelines

  • Install the module in designated rack slots per 3300 system allocation.
  • Ensure correct AC input wiring and verify jumper configuration before energizing.
  • Ground the chassis to dissipate electrostatic discharge.
  • Maintain ambient conditions within specified operating and storage ranges.
  • Route transducer wiring separately from high-voltage conductors to minimize interference.
  • Confirm fuse rating matches the configured input voltage range.