Vendor: Bently Nevada

Bently Nevada 3300/16-15-01-01-00-00-01 XY/Gap Dual Vibration Monitor Module

SKU: 3300/16-15-01-01-00-00-01
In stock
Description

Bently Nevada 3300/16-15-01-01-00-00-01 XY/Gap Dual Vibration Monitor Module

The Bently Nevada 3300/16-15-01-01-00-00-01, also cataloged as the 3300/16 XY/Gap Dual Vibration Monitor, operates as a dedicated hardware component for dual-channel radial vibration and shaft position monitoring within the 3300 machinery protection system.

Hardware Specifications

Parameter Specification
Model 3300/16-15-01-01-00-00-01
Brand Bently Nevada
Origin USA
Weight 0.6kg
Dimensions Standard rack module form factor
Operating Temp -40 deg C to +85 deg C
Power Consumption Supplied via rack backplane
Channels 2 independent radial vibration channels
Input Range 0–15 mils pp (0–500 µm pp)
Input Impedance 10 kΩ
Accuracy ±0.5% of full-scale at +25 deg C
Transducer Inputs 3300 8 mm, 3300 XL 8 mm, 7200 5 mm/8 mm Proximitor (200 mV/mil)
Transducer Supply -24 VDC or -18 VDC, current limited
Recorder Outputs +4 to +20 mA, max load 600 Ω
Alarm Relays Epoxy-sealed dual relays (Alert and Danger)
Alarm Adjustability 0–100% of full-scale
Alarm Repeatability ±0.39% of full-scale
Gap Alarm Delay 6 seconds
Trip Multiply 2X scaling via external contact closure
Humidity 95% non-condensing

Rotor Dynamics and Cross-Talk Suppression

The module integrates eddy-current probe scaling to maintain accurate displacement and vibration measurements. Gap voltage validation against -10 VDC reference points ensures probe integrity. Internal architecture suppresses cross-talk between channels, preserving deterministic rotor dynamics tracking during continuous online monitoring of turbines, compressors, and pumps.

Frequently Asked Questions

Q: Can the 3300/16 module be hot-swapped in the rack? A: No. Removal or insertion under power is not recommended due to potential bus disturbances.

Q: How does Trip Multiply function during startup? A: External contact closure doubles alarm setpoints, preventing nuisance trips during machine acceleration or coast-down.

Q: Are recorder outputs short-circuit protected? A: Yes. The +4 to +20 mA outputs are short-circuit protected with a maximum load of 600 Ω.

Field Installation Guidelines

  • Install only in designated rack slots to avoid interference with system modules.
  • Route probe wiring separately from power cabling to minimize EMI.
  • Confirm grounding of rack chassis and shield connections.
  • Validate probe gap voltage (-10 VDC reference) during commissioning.
  • Maintain airflow clearance around the rack for thermal management.