Vendor: Bently Nevada

Bently Nevada 3300/20-12-01 Dual Thrust Position Monitor

SKU: 3300/20-12-01
In stock: 5
Description

Bently Nevada 3300/20-12-01 Dual Thrust Position Monitor

Configured for dual-channel thrust displacement monitoring in the 3300 machinery protection system, the Bently Nevada 3300/20-12-01 (3300/20 Dual Thrust Position Monitor) provides direct axial shaft position measurement and alarm execution.

Suffix Breakdown & Model Matrix

  • Range Option (-12): Configured for ±50 mils (±1.27 mm) axial displacement, scaled at 200 mV/mil (7.87 V/mm).
  • Transducer Option (-01): Compatible with 3300 and 7200 series 5 mm/8 mm Proximitor sensor systems.
  • Rack Slot Requirements: Occupies two slots in the 3300 monitor rack.
  • Outputs: Provides 4-20 mA or 1-5 VDC recorder outputs per channel.
  • Alarm Functions: Adjustable alert/danger thresholds with relay logic for "OK", "Alert", and "Danger".

Hardware Specifications

Parameter Specification
Model 3300/20-12-01
Brand Bently Nevada
Origin USA
Weight Not specified
Dimensions Rack slot module, dual-width
Operating Temp Standard 3300 system range (industrial ambient)
Power Consumption Low-voltage rack supply
Core Performance Dual-channel thrust position monitoring, ±50 mils range, 200 mV/mil scaling

Eddy-Current Probe Scaling and Gap Voltage Validation

The monitor applies linear scale factors aligned with Bently Nevada proximity probes, ensuring accurate conversion of eddy-current signals into axial displacement values. Gap voltage validation is performed against -10 VDC reference targets, confirming probe installation integrity and signal conditioning stability. This mechanism supports rotor dynamics analysis and suppresses cross-talk between dual channels.

Frequently Asked Questions

Q: Does the 3300/20-12-01 support hot-swap installation? A: No, modules require rack power-down before insertion or removal to prevent backplane signal disruption.

Q: What is the expected backplane current load for this monitor? A: It draws standard low-voltage rack supply current; exact values depend on rack configuration but remain within 3300 system design limits.

Q: How are alarm relay transitions handled under redundant rack configurations? A: Relay logic executes with minimal delay, typically within mechanical relay switching time, ensuring deterministic alert/danger signaling.

Field Installation Guidelines

  • Ensure proximity probe cabling is shielded and properly grounded at the rack end to minimize induced noise.
  • Maintain probe gap voltage near -10 VDC during installation for valid displacement scaling.
  • Route dual-channel inputs separately to reduce cross-talk and maintain rotor dynamics fidelity.
  • Secure module into designated dual-width rack slots; verify backplane connectors are fully engaged.
  • Configure alert and danger setpoints via rack interface before commissioning.