Vendor: Bently Nevada

Bently Nevada 3300/45-02-02-03-00 Dual Differential Expansion Monitor

SKU: 3300/45-02-02-03-00
In stock: 15
Description

Bently Nevada 3300/45-02-02-03-00 Dual Differential Expansion Monitor

Configured for dual-channel differential expansion monitoring in turbine supervisory instrumentation networks, the Bently Nevada 3300/45-02-02-03-00 (3300/45 Dual Differential Expansion Monitor) provides direct physical execution of displacement measurement and alarm relay signaling.

Suffix Breakdown & Model Matrix

  • -02 (Full-Scale Range): 0 to 10 mm peak-to-peak displacement.
  • -02 (Transducer Input): Designed for 50 mm (2.0 inch) extended-range proximity transducer systems.
  • -03 (Alarm Relays): Quad Relay Module with independent Alert and Danger dry-contact relays for both channels.
  • -00 (Agency Approval): Standard factory configuration, no hazardous area certifications.

Hardware Specifications

Parameter Specification
Model 3300/45-02-02-03-00
Brand Bently Nevada
Origin USA
Weight ~1.0 kg
Dimensions Dual-width rack slot module
Operating Temp 0 to +65 deg C
Power Consumption Drawn from 3300 rack backplane
Core Performance Two independent monitoring channels, ±0.5% accuracy, 4-20 mA recorder outputs

Rotor Dynamics and Gap Voltage Validation

The monitor integrates rotor dynamics evaluation by tracking axial differential expansion across two channels. Gap voltage validation against -10 VDC reference points ensures probe calibration accuracy. Internal conditioning suppresses cross-talk between probes, maintaining fidelity in multi-sensor configurations.

Frequently Asked Questions

Q: Can the 3300/45-02-02-03-00 be hot-swapped in the rack? A: No, modules require rack power-down before insertion or removal to avoid backplane disturbance.

Q: What recorder outputs are provided per channel? A: Each channel delivers independent 4-20 mA DC linearized outputs for PLC/DCS integration.

Q: How are alarm relays configured? A: Quad relay configuration provides epoxy-sealed dry contacts with Alert and Danger outputs for both channels.

Field Installation Guidelines

  • Install into designated dual-width rack slots with full connector engagement.
  • Ensure proximity probe wiring is shielded and grounded at the rack end only to prevent ground loops.
  • Route signal cabling separately from high-voltage conductors to minimize induced noise.
  • Validate probe gap voltage near -10 VDC before commissioning to confirm displacement scaling.
  • Configure alarm setpoints digitally via front panel switches prior to system startup.