Bently Nevada 3300/48-02-01-00-00 Case Expansion Monitor
Bently Nevada 3300/48-02-01-00-00 Case Expansion Monitor
The Bently Nevada 3300/48-02-01-00-00, also cataloged as the 3300/48 Case Expansion Monitor, operates as a dedicated hardware component for casing expansion measurement within the 3300 rack-based system.
Suffix Breakdown & Model Matrix
- -02 (Input Option): Single-channel or dual-channel LVDT input configuration.
- -01 (Agency Approval): CSA / NRTL / C Class I, Division 2 compliance.
- -00 (Internal Barriers): None installed.
- -00 (Display Unit): Standard millimetres or mils depending on scale selection.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 3300/48-02-01-00-00 |
| Brand | Bently Nevada |
| Origin | USA |
| Weight | Approx. 0.9 kg |
| Dimensions | Single-slot rack module |
| Operating Temp | 0 to +65 deg C |
| Power Consumption | 18 to 36 VDC via rack backplane |
| Core Performance | Dual-level alarms, ±1% accuracy, 4-20 mA or 1-5 VDC recorder outputs |
Rotor Dynamics and Cross-Talk Suppression
The monitor integrates rotor dynamics evaluation by processing casing expansion signals from LVDTs. Buffered outputs provide raw voltage signals for diagnostic analyzers. Internal conditioning suppresses cross-talk between channels, ensuring accurate comparative displacement tracking.
Frequently Asked Questions
Q: What recorder outputs are available? A: The module supports both 4-20 mA and 1-5 VDC proportional outputs for PLC/DCS integration.
Q: How are alarm setpoints configured? A: Alert and Danger thresholds are set via internal jumpers, providing deterministic relay switching.
Q: Can buffered outputs be used for diagnostics? A: Yes, front-panel coaxial connectors deliver unfiltered raw signals for analyzer troubleshooting.
Field Installation Guidelines
- Insert into a single-slot rack position with full connector engagement.
- Ensure LVDT cabling is shielded and grounded at the rack end only.
- Route signal wiring separately from high-voltage conductors to minimize induced noise.
- Validate displacement calibration during commissioning using reference displacement blocks.
- Configure alarm setpoints internally before system startup.
Bently Nevada 3300/48-02-01-00-00 Case Expansion Monitor