Bently Nevada 3300/65-14-01-00-00-01-00 Dual Probe Monitor Module

SKU: 3300/65-14-01-00-00-01-00
In stock: 15
Description

Bently Nevada 3300/65-14-01-00-00-01-00 Dual Probe Monitor Module

The Bently Nevada 3300/65-14-01-00-00-01-00, also cataloged as the 3300/65 Dual Probe Monitor Module, operates as a dedicated hardware component for vector summation of shaft relative displacement and casing vibration within the 3300 monitoring system.

Hardware Specifications

Parameter Specification
Model 3300/65-14-01-00-00-01-00
Brand Bently Nevada
Origin USA
Weight Approx. 1.0 kg
Dimensions Not specified
Operating Temp -20 deg C to +65 deg C
Power Consumption Not specified
Signal Processing Vector summation of proximity probe and velocity transducer signals
Frequency Response 4 Hz to 4,000 Hz
Accuracy ±1% of full-scale range
Recorder Outputs 4-20 mA or 1-5 VDC linear scaling
Transducer Type 3300/7200 Series 8 mm Proximity Probe & Seismoprobe Velocity Transducer
Relay Option Epoxy-sealed relays
Agency Approval None
Intrinsic Safety None

Eddy-Current Probe Scaling and Gap Voltage Validation

This module integrates eddy-current probe scaling to ensure accurate displacement measurement across the specified 50-0-50 mil range. Gap voltage validation is performed against -10 VDC targets to confirm probe linearity and maintain rotor dynamics fidelity. Signal cross-talk suppression is embedded in the design to minimize interference between displacement and velocity channels.

Frequently Asked Questions (FAQ)

Q: Does the 3300/65 module support hot-swap replacement? A: No, removal or insertion under power is not recommended due to backplane bus current stability requirements.

Q: What is the typical switching delay for epoxy-sealed relay outputs in redundant configurations? A: Relay switching delay is within standard mechanical relay tolerances, typically under 20 ms, without additional trip multiplication logic.

Q: Are firmware upgrades required for compatibility with newer 3300 rack systems? A: The module operates with baseline firmware flash compatibility across the 3300 rack series, no upgrade is required for standard monitoring functions.

Field Installation Guidelines

  • Ensure shielded cable terminations are grounded at a single point to reduce induced noise.
  • Maintain probe cabling separation from high-voltage conductors to avoid signal distortion.
  • Observe rack slot alignment and secure module insertion to prevent connector wear.
  • Verify BNC connectors are firmly engaged when connecting external diagnostic equipment.
  • Maintain ambient humidity below 95% non-condensing during installation.