Vendor: Bently Nevada

Bently Nevada 330801-28-05-101-03-02 Proximity Sensor

SKU: 330801-28-05-101-03-02
In stock: 15
Description

Bently Nevada 330801-28-05-101-03-02 Proximity Sensor

The Bently Nevada 330801-28-05-101-03-02, also cataloged as the 330801 proximity sensor, serves as an 8 mm transducer system for shaft vibration and position monitoring in rotating machinery.

Part Number Breakdown

  • Model (330801): 8 mm proximity probe / transducer system
  • Suffix (28): Series option (specific to 330801 family)
  • Suffix (05): Probe configuration option
  • Suffix (101): Cable length / assembly variant
  • Suffix (03): Mounting fittings option
  • Suffix (02): Miniature coaxial ClickLoc connector

Hardware Specifications

Parameter Specification
Model 330801-28-05-101-03-02
Brand Bently Nevada
Origin USA
Weight Not specified
Dimensions Tip diameter 8 mm; linear range 2 mm (80 mils)
Operating Temp -40 deg C to +85 deg C (-40 deg F to +185 deg F)
Power Consumption Passive probe, excitation via proximitor
Core Performance Output sensitivity 200 mV/mil (7.87 V/mm); frequency response 0 Hz to 10 kHz; 3/4-14 NPT mounting interface

Eddy-Current Probe Scaling and Rotor Dynamics

The sensor operates on the eddy-current principle, translating magnetic field interactions into linear voltage outputs. Standard sensitivity is 200 mV/mil, with a linear range of 2 mm. Gap voltage validation at -10 VDC ensures balanced measurement of shaft movement in both directions. Coaxial shielding suppresses cross-talk, maintaining signal fidelity in multi-probe installations.

Frequently Asked Questions

Q: Can the 330801 sensor measure both static and dynamic displacement? A: Yes. It measures static shaft position and dynamic vibration simultaneously.

Q: Is the mounting interface standardized? A: Yes. The probe uses a 3/4-14 NPT mounting interface for compatibility with standard housings.

Q: Does frequency response extend into higher ranges? A: The probe supports 0 Hz to 10 kHz, sufficient for most turbomachinery vibration monitoring applications.

Field Installation Guidelines

  • Engage 3/4-14 NPT threads with minimum 5 turns for mechanical stability.
  • Ground shielding at the proximitor end only to prevent ground-loop interference.
  • Route cables away from high-voltage conductors to minimize induced noise.
  • Verify -10 VDC gap voltage reference during commissioning for accurate displacement scaling.
  • Confirm hazardous area approvals before installation in classified zones.