The UR 9NV is engineered to provide comprehensive protection, control, monitoring, and supervision for power systems across various applications, including generation, transmission, distribution, substations, and industrial environments. Its modular design ensures high performance and flexibility, making it suitable for a wide range of power asset management tasks.

Key Features and Specifications

Protection and Control

  • Line Current Differential Protection: Fast and segregated line current differential with adaptive restraint, providing precise fault detection and isolation.
  • Phase Segregated Protection: Includes phase segregated line current differential and ground differential protection for enhanced fault discrimination.
  • Distance Protection: Offers phase distance protection with five independent zones and adjustable compensation settings for accurate fault location.
  • Breaker-and-Half Support: Supports single-pole tripping and breaker-and-a-half configurations with independent current source support for flexible system design.
  • Generator Protection: Comprehensive protection for generators, including 100% stator ground fault detection and field ground protection to safeguard critical equipment.

Monitoring and Metering

  • Synchrophasors: Optional support for IEEE C37.118 (2011) and IEC 61850-90-5 synchrophasors for advanced system monitoring.
  • Advanced Recording: Equipped with a 1024-event recorder, configurable waveform capture, and a data logger for detailed event analysis and historical data review.
  • Fault Locator: Integrated fault locator with user-programmable fault reports to facilitate quick fault analysis and resolution.
  • Breaker Monitoring: Monitors breaker conditions including arcing current (I2t), re-strike events, and flashovers to ensure reliable breaker performance.

Communications

  • Robust Connectivity: Features up to 8 HardFiber Bricks for high-speed and reliable communication.
  • Redundant Architecture: Ensures system dependability and security with a redundant design that maintains operation during component failures.
  • Ethernet Ports: Three Ethernet ports support purpose-specific LANs, reducing latency and improving communication efficiency by isolating critical traffic from heavy network loads.

Applications

  • Power Asset Management: Ideal for protection, control, monitoring, and supervision of power assets in diverse environments.
  • Substation Automation: Suitable for utility substation automation and industrial plant control.
  • Fault and Event Recording: Capable of digital fault recording and Sequence of Event (SOE) recording for precise fault analysis and system diagnostics.
  • Predictive Maintenance: Utilizes data analysis and trending to support predictive maintenance strategies, enhancing system reliability and performance.

GE Multilin UR-9NV UR 9NV Power Supply Module

SKU
UR9NV
Manufacturer
General Electric
Product Type
Power Supply Module
Product Origin
USA
Condition
Brand New
Payment
T/T
Weight
0.6 kg
Shipping port
Xiamen
Warranty
12 months
Fast Worldwide Shipping

Contact us for shipping options, freight costs and estimated delivery times.

12-Month Warranty

Your purchase is covered by our 12-month supplier warranty. Contact us for warranty assistance.

30-Day Returns

Eligible products can be returned within 30 days. Contact our team to arrange your return.

Expert Support

Our team helps you check part numbers, confirm availability and answer your ordering questions.

Description

Description

The UR 9NV is engineered to provide comprehensive protection, control, monitoring, and supervision for power systems across various applications, including generation, transmission, distribution, substations, and industrial environments. Its modular design ensures high performance and flexibility, making it suitable for a wide range of power asset management tasks.

Key Features and Specifications

Protection and Control

  • Line Current Differential Protection: Fast and segregated line current differential with adaptive restraint, providing precise fault detection and isolation.
  • Phase Segregated Protection: Includes phase segregated line current differential and ground differential protection for enhanced fault discrimination.
  • Distance Protection: Offers phase distance protection with five independent zones and adjustable compensation settings for accurate fault location.
  • Breaker-and-Half Support: Supports single-pole tripping and breaker-and-a-half configurations with independent current source support for flexible system design.
  • Generator Protection: Comprehensive protection for generators, including 100% stator ground fault detection and field ground protection to safeguard critical equipment.

Monitoring and Metering

  • Synchrophasors: Optional support for IEEE C37.118 (2011) and IEC 61850-90-5 synchrophasors for advanced system monitoring.
  • Advanced Recording: Equipped with a 1024-event recorder, configurable waveform capture, and a data logger for detailed event analysis and historical data review.
  • Fault Locator: Integrated fault locator with user-programmable fault reports to facilitate quick fault analysis and resolution.
  • Breaker Monitoring: Monitors breaker conditions including arcing current (I2t), re-strike events, and flashovers to ensure reliable breaker performance.

Communications

  • Robust Connectivity: Features up to 8 HardFiber Bricks for high-speed and reliable communication.
  • Redundant Architecture: Ensures system dependability and security with a redundant design that maintains operation during component failures.
  • Ethernet Ports: Three Ethernet ports support purpose-specific LANs, reducing latency and improving communication efficiency by isolating critical traffic from heavy network loads.

Applications

  • Power Asset Management: Ideal for protection, control, monitoring, and supervision of power assets in diverse environments.
  • Substation Automation: Suitable for utility substation automation and industrial plant control.
  • Fault and Event Recording: Capable of digital fault recording and Sequence of Event (SOE) recording for precise fault analysis and system diagnostics.
  • Predictive Maintenance: Utilizes data analysis and trending to support predictive maintenance strategies, enhancing system reliability and performance.

Ordering & Support FAQs

Information on product condition, availability, payment, shipping, warranty and returns.

ABB, HIMA and Emerson industrial automation modules arranged on a dark studio background.

Availability is confirmed by the complete part number and required quantity. Most confirmed in-stock items can be dispatched the same day when cleared payment is received before 2:00 PM (UTC+8). Special-order items typically require 1–3 weeks, subject to availability. Please confirm urgent dispatch with us before ordering.

Your quotation will specify the condition and packaging of the offered item. New parts are unused. “New in sealed packaging” means the original package seal is intact. For “new in original packaging” items, the seal condition is confirmed separately. Please specify any packaging or documentation requirements when enquiring.

The shipping origin depends on the stock allocated to your order and is stated in your quotation or pro forma invoice, together with the Incoterm. Freight is quoted separately based on the shipment and destination. Please provide your delivery address, postcode and contact details. Your preferred carrier or courier account can also be considered.

We accept bank wire transfers in CNY (RMB), GBP, EUR or USD. RUNTO ELECTRIC does not accept credit cards or offer credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.

RUNTO ELECTRIC provides a 12-month limited supplier warranty from the shipment date, unless your quotation or invoice states otherwise. It applies to the direct purchaser and cannot be transferred to an end customer. This is not an OEM or international manufacturer warranty. An order-specific warranty confirmation letter is available on request.

Eligible products can be returned within 30 days under our return policy. Please provide your order number and reason for return before sending the item back. Our team will confirm eligibility and provide return instructions.

Reviews & buying guides

From the tech desk